Battery charger NG3 CANBUS English
D01737-01 7
Micro-fit contacts CANBUS connector pinout
Pin N° Description Pin N° Description
1 Pump pressure sensor
1 CAN low
2 Generic digital input
2 CAN low
3 GND
3 CAN negative
4 Hardware S/S
4 +12V (internal)
5 GND
5 CAN high with termination (120)
6 Not used
6 GND (internal)
7 PPT100
7 CAN high
8 NPT100
8 CAN high
9 Green LED
9 CAN positive
10 GND
11 Red LED
1 7
8
2
3 9
10
4
5 11
12
6
12 Not used
Auxiliary Contacts
Nominal current/Max instant current A 2/3
Nominal voltage/ Max voltage commutable Vac 125/250
Nominal load in AC1 VA 125
Nominal load in AC15 (230Vac) VA 25
Single phase engine capacity (230 Vac) Kw -
Break power in DC1: 30/110/220 VA 2/0.3/-
Minimum mW commutable charge (V/mA) 10 (0.1/1)
Mechanical length AC/DC cycles
—/10×10
6
Electrical duration with nominal charge in A1 cycles 100×10³
Isolation according EN 61810-1 2nd edition 1.2 kV/2
Isolation between coil and contacts (1.2/50 µs) kV 1.5
Dielectric rigidness between open contacts Vac 750
Unless otherwise stated, the auxiliary contacts provide the following functions:
Section Function Description
AUX1 Mains Presence
When the equipment is switched on, the contact Normally Open (NO)
CLOSES and instead the contact Normally Closed (NC) OPENS.
AUX2 End of charge
When the Stop Phase is reached, the contact Normally Open (NO)
CLOSES and instead the contact Normally Closed (NC) OPENS.